KV50-200 MK3 Test System

KV50-200 MK3 Test System

0-50kV output voltage 5kVA output capability Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip – 10-110% of rated output Voltage and current metering External interlock circuit Zero-volt interlock Visual indication of test piece failure The KV50-200 MK2 Test System is a high power, high voltage ac test set designed for insulation testing. This system is equally suited to both development and routine testing of electrical insulation systems and plant. The equipment consists of a control unit and a separate oil filled high voltage transformer, linked by 5 meter supply and control cables. The control unit is fitted with a comprehensive range of facilities for control, metering and protection. The system includes a secondary tap metering as standard to ensure accurate voltage metering. The output voltage and current are displayed on large, linear analogue instruments, and a variable electronic trip is provided, allowing the trip current to be set to 10-110% of rated output. The high voltage transformer is housed in an oil-filled steel tank fitted with swivel castors for mobility. The units use a low-discharge oil-filled bushing for the HV output. The KV50-200 MK2 Test System is equally suited to testing capacitive, resistive or inductive test objects. The output of the units are protected by variable electronic trips monitoring the output current, and a fixed over-current trip on the primary of the output transformer. The variable trip is adjustable in 10% steps between 10% and 110% of the rated output current. The input and control supplies are protected by fuses. An earth terminal is provided on the transformer which must be connected to a low impedance local earth. WEIGHT 37 kg DIMENSIONS 370 × 480 × 290 mm TRANSFORMER WEIGHT 220 kg TRANSFORMER DIMENSIONS 570 x 500 x 1020 mm SUPPLIED ACCESSORIES Supply lead Spare fuse set Operating manual Earth lead
STS 3000 LIGHT Multifunction substation test set

STS 3000 LIGHT Multifunction substation test set

STS 3000 light is a testing system designed to perform Tan Delta and capacitance measurement on CTs, VTs, Power Transformer and Circuit Breaker Main features Fully automatic Variable output frequency: 15 – 500 Hz Output voltage up to 12 kV Power dissipation factor test with the module TD 5000 ( voltage up to 12 kV) PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Compact and lightweight. Tests performed Tangent Delta Capacitance
STS 3000 LIGHT Multifunction substation test set

STS 3000 LIGHT Multifunction substation test set

STS 3000 light is a testing system designed to perform Tan Delta and capacitance measurement on CTs, VTs, Power Transformer and Circuit Breaker Main features Fully automatic Variable output frequency: 15 – 500 Hz Output voltage up to 12 kV Power dissipation factor test with the module TD 5000 ( voltage up to 12 kV) PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Compact and lightweight. Tests performed Tangent Delta Capacitance
STS 5000 Multifunction substation test set

STS 5000 Multifunction substation test set

STS 5000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid. Main features Fully automatic Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000 Variable output frequency: 15 – 500 Hz Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV) 2000 v AC high-pot test Local control by large color display PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report IEC 61850-9-2 communication protocol Patented technology for Capacitance and Tan Delta measurement USB interface and Ethernet interface for PC connection. Compact and lightweight Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side ALF ISF CT excitation curve CT knee voltage CT winding resistance burden resistance voltage withstand rogowski coil low power transformer CT IEC 61850-9 VT ratio VT polarity VT burden secondary side VT IEC 61850-9 PT ratio PT vector group PT winding resistance OLTC tap changer dynamic resistance; PT excitation current PT no load current PT short circuit impedance PT leakage reactance Micro-ohmmeter CB operation time
STS 5000 Multifunction substation test set

STS 5000 Multifunction substation test set

STS 5000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid. Main features Fully automatic Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000 Variable output frequency: 15 – 500 Hz Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV) 2000 v AC high-pot test Local control by large color display PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report IEC 61850-9-2 communication protocol Patented technology for Capacitance and Tan Delta measurement USB interface and Ethernet interface for PC connection. Compact and lightweight Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side ALF ISF CT excitation curve CT knee voltage CT winding resistance burden resistance voltage withstand rogowski coil low power transformer CT IEC 61850-9 VT ratio VT polarity VT burden secondary side VT IEC 61850-9 PT ratio PT vector group PT winding resistance OLTC tap changer dynamic resistance; PT excitation current PT no load current PT short circuit impedance PT leakage reactance Micro-ohmmeter CB operation time
SOLARANLAGE DF50 HEIZUNG & WARMWASSER FASSADE/FLACHDACH

SOLARANLAGE DF50 HEIZUNG & WARMWASSER FASSADE/FLACHDACH

Solarthermische Anlage zur Brauchwassererwärmung und Heizungsunterstützung zur Installation an der Fassade oder auf dem Flachdach. Art.-Nr. 18050 bestehend aus: 1 x Kollektor Weiser Power 3000 (Direct Flow Kollektor mit 30 Powerröhren) 1 x Kollektor Weiser Power 2000 (Direct Flow Kollektor mit 20 Powerröhren) 1 x Set Gehäuseverbinder 1 x Set Enddeckel 2 x Befestigungsset Fassade oder Flachdach 1 x Anschlußset Wellrohr 3 x 20 kg Wärmeträgermedium VT51 df Allgemein: - 4-fach höherer Wirkungsgrad als bei Solarmodulen zur Stromerzeugung - 100% Made in Germany - dauerhafter Schutz des Vakuums durch patentierte Glas-Metall-Verbindung - witterungsbeständige Nanobeschichtung verhindert Schmutzanhaftungen - 20 Jahre Herstellergarantie - Röhren um 360° drehbar und optimal zur Sonne ausrichtbar - gleicher Röhrenabstand bei Verschaltung mehrerer Kollektoren - leichte Montage ohne schweres Werkzeug durch Steckverbindung - Röhren steckbar an Verteiler mit Schnellwechselmöglichkeit angeschlossen - für die optisch perfekte Anpassung an Dach und Fassade sind die Kollektoren in 213 RAL Farben lieferbar - Kollektoren sind TÜV geprüft nach DIN EN 12975-1:2006-06, DE EN 12975-2:2006-06, Solar Keymark Registernr.: 011-7S471R - Hagelschlag getestet nach: DIN EN 12975-2:2006
SOLARANLAGE DF30 ANLAGE BRAUCHWASSER FLACHDACH/FASSADE

SOLARANLAGE DF30 ANLAGE BRAUCHWASSER FLACHDACH/FASSADE

Solarthermische Warmwasseranlage zur Brauchwassererwärmung zur Installation an der Fassade oder auf dem Flachdach Art.-Nr. 18030 1 x Kollektor Weiser Power 3000 (Direct Flow Kollektor mit 30 Powerröhren) 1 x Set Enddeckel 1 x Befestigungsset Fassade oder Flachdach 1 x Anschlußset Wellrohr 2 x 20 kg Wärmeträgermedium VT51 df Die Röhren können einzeln um 360° gedreht und somit immer optimal zur Sonne ausgerichtet werden, auch wenn der Installationsort nicht 100%tig nach Süden ausgerichtet ist.
SOLARANLAGE DF60 HEIZUNG & WARMWASSER FASSADE/FLACHDACH

SOLARANLAGE DF60 HEIZUNG & WARMWASSER FASSADE/FLACHDACH

Solarthermische Anlage mit 60 df Röhren zur Brauchwassererwärmung und Heizungsunterstützung zur Installation an Fassade oder Flachdach. Art.-Nr. 18060 bestehend aus: 2 x Kollektor Weiser Power 3000 (Direct Flow Kollektor mit 30 Powerröhren) 1 x Set Gehäuseverbinder 1 x Set Enddeckel 2 x Befestigungsset Fassade oder Flachdach 1 x Anschlußset Wellrohr 3 x 20 kg Wärmeträgermedium VT51 df Allgemein: - 4-fach höherer Wirkungsgrad als bei Solarmodulen zur Stromerzeugung - 100% Made in Germany - dauerhafter Schutz des Vakuums durch patentierte Glas-Metall-Verbindung - witterungsbeständige Nanobeschichtung verhindert Schmutzanhaftungen - 20 Jahre Herstellergarantie - Röhren um 360° drehbar und optimal zur Sonne ausrichtbar - gleicher Röhrenabstand bei Verschaltung mehrerer Kollektoren - leichte Montage ohne schweres Werkzeug durch Steckverbindung - Röhren steckbar an Verteiler mit Schnellwechselmöglichkeit angeschlossen - für die optisch perfekte Anpassung an Dach und Fassade sind die Kollektoren in 213 RAL Farben lieferbar - Kollektoren sind TÜV geprüft nach DIN EN 12975-1:2006-06, DE EN 12975-2:2006-06, Solar Keymark Registernr.: 011-7S471R - Hagelschlag getestet nach: DIN EN 12975-2:2006
ART3V RELAY TEST SYSTEM

ART3V RELAY TEST SYSTEM

3-f Voltage output from 1-f supply 0-450V f-N output voltage 20VA/phase maximum output Variable Frequency 30-999.9Hz Phase shift ±180.0° Multi-function timing system USB keyboard for comment USB data storage. Ideally suited to testing G59 & G99 schemes Step change of phase and df/dt Large 6.5” back-lit colour LCD Automatic mains voltage selection Fully Programmable test procedures Rugged case and weighs under 9kg The new ART3V Relay Test System brings new features to our range of relay test equipment making it far more adaptable. The new output voltages are higher and have a finer level of accuracy and control. The new full colour LCD provides more test detail, making it easy to understand. The ART3V user interface is an improvement of the DVS3 mk2 allowing simple testing of complex voltage and loss of mains protection systems. The ART3V has vastly improved accuracy, stability, and features. Designed to be the trusted and reliable voltage source for relay testing. The ART3V has been designed using the latest digital technology to generate a highly stable and accurate output with very low distortion. Each phase output is individually adjustable for voltage, frequency and phase angle. The unit is controlled by a simple user interface within defined menus. Values may be either typed in at the capacitive keypad or finely varied using a smooth rotary encoder. Bespoke test procedures can be created for step changes of any output variable at set times or with automatic timing of the response of the relay under test. The ART3V has a colour back-lit display to provide an easy to read user interface. Menu options are selected by dedicated buttons on the panel, allowing easy mode change. All information is displayed including contact set status, and a phasor diagram. The ART3V Relay Test System is ideally suited for testing G59/G99 protection, including loss of mains protection. Vector surge and df/dt (ROCOF) relays can be simply tested and timed, as well as other protection requiring one to three voltages, including: Under and over frequency relays Under and over voltage relays Synchronising relays df/dt & ROCOF relays Vector surge relays Transducers In conjunction with the ART3C or a current source (such as the 200ADM-P), the ART3V can be used to test protection circuits, including: Directional relays Distance protection Phase angle relays Power relays Power transducers Output The output of the ART3V has 4mm safety sockets for phases A, B, C and neutral. The neutral connection may be omitted for a delta connection. The neutrals can be linked for a star connection using the provided accessory. Timing System The timing system on the ART3V is flexible and transparent with different modes of operation. USB Data The ART3V can be connected to a USB keyboard for adding comments to tests. Each test is stored to a USB memory key with each comment. The data is stored in a *.CSV format allowing it to be opened in all types of desktop PC spreadsheet software. Modes of Operation Output Adjust This mode allows full control of frequency, voltage and phase. Phase Lock Mode The frequency and phase of the output can be controlled by an external reference in phase lock mode. The reference may be the mains supply to the ART3V, an external voltage, current. This mode allows testing of directional and distance protection in conjunction with an external current source. Fault Config Mode Fault Config mode allows extra flexibility in testing complex timed events or several sets of values that must be applied to a relay in turn. This mode allows three sets of values to be set in advance (pre-fault, fault, and post-fault values). The ART3V may be set to switch from one state to the next on a change of contact or after a specific time. In addition, the timer may be set to start or stop on any one of the state changes or a change of contact state. This mode allows frequency, phase and voltage to be changed simultaneously if required. Test configurations can be save to USB. More complex configurations can be loaded from the USB, such as a complete G59/G99 relay test, such as relay stability tests. df/dt and ROCOF (Rate Of Change Of Frequency) Loss of mains protection often takes the form of a df/dt relay, sensitive to the rate of change of frequency over time. The ART3V is able to generate a swept frequency output with accurate rates of change of frequency between preset frequencies. WEIGHT 8.9 kg DIMENSIONS 419 × 325 × 195 mm SUPPLIED ACCESSORIES Output lead set Lead set case Mains lead Spare fuse set Operating manual
KV30-100 MK3 Test System

KV30-100 MK3 Test System

0-30kV output voltage 3kVA output capability Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip – 10-110% of rated output Voltage and current metering External interlock circuit Zero-volt interlock Visual indication of test piece failure The KV30-100 MK2 Test System is a high power, high voltage ac test system designed for insulation testing. This system is equally suited to both development and routine testing of electrical insulation systems and plant. The equipment consists of a control unit and a separate oil filled high voltage transformer, linked by 5 metre supply and control cables. The control unit is fitted with a comprehensive range of facilities for control, metering and protection. The output voltage and current are displayed on large, linear analogue instruments, and a variable electronic trip is provided, allowing the trip current to be set to 10-110% of rated output. The high voltage transformer is housed in an oil-filled steel tank fitted with swivel castors for mobility. The unit uses a high voltage bushing for the HV output, and the other end of the HV winding is earthed. The output of the units are protected by variable electronic trips monitoring the output current, and a fixed over-current trip on the primary of the output transformer. The variable trip is adjustable in 10% steps between 10% and 110% of the rated output current. The input and control supplies are protected by fuses. The KV30-100 MK2 Test System is equally suited to testing capacitive, resistive or inductive test objects. If higher voltage or output power is required, please refer to our KV50-200/KV100-100 data sheet, detailing our 10kVA high voltage systems. WEIGHT 25 kg DIMENSIONS 370 × 480 × 290 mm TRANSFORMER WEIGHT 210 kg TRANSFORMER DIMENSIONS 480 x 460 x 570 mm SUPPLIED ACCESSORIES Supply lead Spare fuse set Operating manual Earth lead
KV30-40D MK3 Test System

KV30-40D MK3 Test System

The output voltage and current are metered by large, accurate true RMS digital meters 0-30kV output voltage 1.2kVA output capability Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip – 10-110% of rated output Test timer Voltage and current metering Zero-volt interlock External 24Vdc interlock circuit Visual indication of test piece failure The KV30-40D MK3 Test System is a high voltage general purpose test instrument designed for testing insulation systems and the measurement of breakdown voltage on electrical plant and components. The unit has an output voltage variable from zero to 30kV with accurate metering on both the output voltage and current. A zero-voltage interlock is provided, ensuring that the output may only be energised with the voltage control at zero. The output voltage and current are metered by large, accurate true RMS digital meters. The meters are backlit and have a digit height of 19mm. The test object and output are protected by an adjustable current trip. The trip level may be set to 10-110% of the rated output in 10% steps. Breakdown of the test object is visibly indicated. The unit must be manually reset after a trip condition before testing can be resumed. A pre-selectable test timer is provided for timed tests of 5, 10, 15, 20, 30 seconds, 1, 2, 3 or 5 minutes. An alarm sounds when the test time has ended. The units feature automatic mains voltage selection and an external 24Vdc interlock circuit for connection of emergency off switches and enclosure interlocks. WEIGHT 42 kg DIMENSIONS 300 × 400 × 470 mm SUPPLIED ACCESSORIES ES30 earthing stick Supply lead Spare fuse set Operating manual Earth lead
KV5-100 MK3 Test System

KV5-100 MK3 Test System

Continuously variable output voltage 0-5kVAC Variable trip circuit 12mA and 20-120mA Output voltage and current metering Visual and audible indication of test piece failure The KV5-100 MK3 Test System is a general purpose, high voltage test instrument designed for testing insulation systems and the measurement of breakdown voltage on electrical plant and components. The unit has an output voltage adjustable from zero to 5kV with accurate metering on both the output voltage and current. A zero-voltage interlock is provided, ensuring that the output may only be energised with the voltage control at zero. The output voltage is metered by a large, linear analogue instrument with a dual-scale marking of 0-3kV and 0-6kV. Load current is metered by a second analogue instrument with 0-10 scale marking. Two current ranges are selectable: 0-10mA and 0-100mA. The test object and output are protected by an adjustable current trip linked to the current metering range. The trip level may be set to 20-120% of the current metering range on 20% steps. Breakdown of the test object is both audibly and visibly indicated. The alarm must be manually reset after a trip condition before testing can be resumed. The KV5-100 MK3 Test System is supplied in a compact and portable case with permanently connected test leads. The test leads are terminated in crocodile clips. The unit is designed to be used in conjunction with an interlocked test enclosure. WEIGHT 16.5 kg DIMENSIONS 364 × 147 × 262 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse
KV50-20D MK3 Test System

KV50-20D MK3 Test System

0-50kV output voltage 20mA maximum output current Auto-selecting 115/230V supply voltage Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip Voltage and current metering External interlock circuit Zero-volt interlock Visual indication of test piece failure Cast resin HV transformer The KV50-20D Mk3 Test System is a low power portable high voltage AC test system designed for insulation testing. This system is equally suited to both development and routine testing of electrical insulation systems and plant. The equipment consists of a control unit and a separate resin cast high voltage transformer linked by a 5 metre control cable. The control unit is housed in a rugged aluminium case with a hinged, removable lid for protection. The high voltage transformer is mounted on a base with swivel castors for mobility. The control unit is fitted with a comprehensive range of facilities for control, metering and protection, including an emergency off switch. The output RMS voltage and current are displayed on digital meters. A variable electronic trip is provided, allowing the trip current to be set to 10-110% of rated output. The KV50-20D Mk3 Test System is designed to be operated with the HV transformer inside an interlock test enclosure. A connector is supplied on the control unit to connect interlock switches, extra emergency stop switches and external 24V beacons. WEIGHT 17 kg DIMENSIONS 380 × 314 × 221 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse
HV TROLLEY2 High Voltage AC Test System

HV TROLLEY2 High Voltage AC Test System

20kVA output capability 0-3kV to 0-15kV options available Accurate digital metering Key operated supply switch Dual overload protection Variable electronic trip 10-110% of rated output Voltage and current metering Optional 5s – 5min test timer External 24V interlock and zero-volt interlock Emergency stop switch The HV trolley2 series of units are high power AC flash test sets with a 20kVA output capability. Single Trolley Version The maximum output voltage can be customised to be any voltage up to 15kV. The unit is housed in a rugged aluminium enclosure with a cover to protect the control panel. It is mounted on wheels to allow easy movement within a production environment. The HV trolley2 is provided with accurate digital voltage and current metering and a variable electronic trip. An external interlock input is also fitted to the unit. Outputs are provided to drive 24V warning beacons. The HV output is connected to the test object by a high voltage cable 5m long.
CPP60-T – Kalibrier-Testpumpe, Pneumatisch, -0,95…+60 bar

CPP60-T – Kalibrier-Testpumpe, Pneumatisch, -0,95…+60 bar

Pneumatisch Prüfdruckerzeugung bis +60 bar (870 psi) Vakuumerzeugung bis -0,95 bar (-28 inHg) Tischmodell Einfache Anwendung Die Kalibrier-Handtestpumpe (Prüfpumpe) CPP 60-T dient zur Druckerzeugung für die Überprüfung, Justage und Kalibrierung von mechanischen und elektronischen Druckmessgeräten durch Vergleichsmessung. Diese Druckprüfungen können stationär im Labor oder in der Werkstatt oder vor Ort an der Messstelle erfolgen. Schließt man das zu prüfende Messgerät und ein ausreichend genaues Referenzmessgerät an der Handtestpumpe CPP 60-T an, so wirkt bei Betätigung der Pumpe auf beide Messgeräte der gleiche Druck. Durch Vergleich der beiden Messwerte bei beliebigen Druckwerten kann eine Überprüfung der Genauigkeit bzw. eine Justage des zu prüfenden Druckmessgerätes erfolgen. Die Handprüfpumpe CPP 60-T ermöglicht trotz ihrer sehr kompakten Abmessungen eine einfache und exakte Prüfdruckerzeugung mit Umschaltmöglichkeit auf Vakuumerzeugung. Für die präzise Einstellung zur genauen Vergleichsprüfung besitzt die CPP 60-T ein Feinregulierventil. Das Referenzmessgerät wird direkt oben auf die Pumpe aufgeschraubt und der Prüfling wird über den im Lieferumfang enthaltenen Anschlussschlauch mit freilaufendem G 1/4″ Innengewinde angeschlossen, ggf. unter Verwendung geeigneter Gewindeadapter. Serienmäßiger Lieferumfang: Kalibriertestpumpe / Prüfpumpe CPP 60-T mit Referenzgeräteanschluss G 1/2″ innen (freilaufend) oben auf der Pumpe und mit Prüflingsanschluss G 1/4″ innen (freilaufend) am Prüflingsanschlussschlauch mit stabiler Bodenplatte mit Gummifüßen Prüflingsanschlussschlauch, Länge 0,5 m Bedienungsanleitung Druckerzeugung: 0 bis 60 bar = 0 bis 870 psi, umschaltbar auf Vakuumerzeugung: 0 bis -0,95 bar = 0 bis -28 inHg Druckanschlüsse (Standardversion): Für Referenzmessgerät: G 1/2″ innen, freilaufend, mit integriertem Dichtring, oben auf der Pumpe. Für Prüfling: G 1/4″ innen, freilaufend, mit integriertem Dichtring, seitlich an der Pumpe, am Prüflingsanschlussschlauch Materialien: Aluminium, Messing, ABS, NBR Vordruckerzeugung: Handhebel Hochdruckerzeugung: Volumenvariator Prüfdruck-Feineinstellung: Volumenvariator (Feinregulierventil mit großem Volumen) Abmessung: ca. 150 x 300 x 215 mm Gewicht: ca. 2,55 kg Artikel-Nr.: CPP-60-T Sonderausführung mit Referenzgeräteanschluss G 1/4″ innen (statt G 1/2″): Artikel-Nr. CPP-60-T-G14 Sonderausführung mit NPT-Gewinden (statt BSP Rohrgewinden): Artikel-Nr. CPP-60-T-N14
Ihre Brillenputztücher im Sachet und individuell bedruckt

Ihre Brillenputztücher im Sachet und individuell bedruckt

Brillenputztücher als Werbung bieten eine praktische und effektive Möglichkeit, das eigene Unternehmen oder die Marke zu bewerben. Brillenputztücher sind kleine Tücher, die speziell für die Reinigung von Brillengläsern entwickelt wurden. Hier sind einige Vorteile und Nutzen von Brillenputztüchern: Reinigung: Brillenputztücher entfernen effektiv Schmutz, Fingerabdrücke, Fett und andere Verunreinigungen von den Brillengläsern. Sie sorgen für eine klare Sicht und verbessern die Brillenleistung. Kratzfreie Reinigung: Brillenputztücher sind weich und schonend für die Brillengläser. Sie verhindern Kratzer und Beschädigungen, die durch unsachgemäße Reinigung mit ungeeigneten Materialien entstehen können. Portabilität: Brillenputztücher sind klein und handlich. Sie können leicht in der Brillenetui, der Tasche oder der Geldbörse aufbewahrt werden, sodass sie jederzeit und überall verfügbar sind. Wiederverwendbarkeit: Viele Brillenputztücher sind wiederverwendbar und können mehrmals verwendet werden, bevor sie ausgetauscht werden müssen. Dadurch sind sie umweltfreundlicher als Einwegreinigungstücher. Vielseitigkeit: Brillenputztücher eignen sich nicht nur für Brillengläser, sondern auch für andere optische Geräte wie Kameralinsen, Smartphone-Bildschirme, Tablets und andere empfindliche Oberflächen, die regelmäßig gereinigt werden müssen. Streifenfreie Reinigung: Brillenputztücher hinterlassen in der Regel keine Streifen oder Rückstände auf den Brillengläsern. Dadurch wird eine klare und saubere Sicht gewährleistet. Hygiene: Brillenputztücher können auch dazu beitragen, Keime, Bakterien und Öle von den Brillengläsern zu entfernen, was besonders wichtig ist, wenn sie von mehreren Personen verwendet werden. Zusammenfassend bieten Brillenputztücher eine bequeme, effektive und schonende Möglichkeit, Brillengläser und andere optische Geräte zu reinigen. Sie verbessern die Sichtqualität, sind leicht zu transportieren und vielseitig einsetzbar.
D4FI – Frequenzanzeiger AN 97 (45x70mm)

D4FI – Frequenzanzeiger AN 97 (45x70mm)

Analoganzeiger (Wechselstrom) für Frequenzmessung, Elektromagnetisches Messwerk Abmessungen : 4 Modul Direkt Spannung Anschluss : 115V – 230V – 400V Skala : 45…55Hz – 45…65Hz – 55…65Hz
EV-TEST100 – Prüfadapter für E-Ladestationen

EV-TEST100 – Prüfadapter für E-Ladestationen

1- und 3-phasiger Prüfadapter mit Stecker Typ 2 zur Simulation von Ladezuständen und zum Prüfen der Wirksamkeit von Schutzmaßnahmen an E-Ladestationen Der EV-Test100 wurde als Zubehör speziell für die Prüfung von E-Ladestationen entwickelt. Er kann zur Simulation von Ladezuständen und zur Prüfung der Wirksamkeit von Schutzmaßnahmen an E-Ladestationen des Typs 3 mit einem Steckverbinder des Typs 2 eingesetzt werden. Die einfache Handhabung in Kombination mit dem Combi G3 bzw. Combi G2 ist garantiert. Messfunktionen Universelle 4mm Buchsen für die Verbindung mit einem 1- oder 3 Phasen-Installations­tester mittels Messleitungen (Bananenstecker) Separate Phasenanzeige durch drei LEDs zur einfachen Spannungsüberprüfung Proximity Pilot (PP) Drehschalter zur Simulation unterschiedlicher Strombelastbarkeiten von Ladekabeln Control Pilot (CP) Drehschalter für die Simulation des elektrischen Fahrzeugstatus A, B,C D Fehler Drehschalter zur Simulation eines Kurzschlusses zwischen CP und PE (Zustand E = Fehler) Simulation PE-Fehler (Erdungsfehler) Anschluss für den CP-Signalausgang zur Überprüfung der Kommunikation zwischen Adapter (=simuliertes Elektrofahrzeug) und Ladestation Typ 2-Stecker für den Anschluss an der Ladestation auch bei fest angeschlossenem Ladekabel Mechanische Verriegelung Dank der Simulation des Fahrzeugstatus es ist möglich zu überprüfen, ob ab Status B die Freigabe des Ladekabel durch die EVSE blockiert wird. (Nur für EVSE mit Verriegelungssystem) Simulation von Fehler PE und CP Durch den entsprechenden Drehschalter ist es möglich, in einer Sequenz die Unterbrechung des Schutzleiters (Fehler PE) und einen Fehler auf dem CP-Signal (Fehler E) zu simulieren. Überwachung des PWM-Ausgangs Durch den Anschluss des CP-Signalausgangs an ein kompatibles HT-Messgerät über das mitgelieferte C100EV-Kabel, ist es möglich sich den Lademodus (A, B, C, D, Fehler) und den Ladestrom anzeigen zu lassen. Fahrzeugsimulation (CP): Die verschiedenen Fahrzeugzustände A bis D können über einen Drehschalter simuliert werden (gemäß IEC 61851) Kabelsimulation (PP): Die verschiedenen Codierungen für Ladekabel mit 13, 20, 32 und 63 A sowie „kein Kabel angeschlossen“ können über einen Drehschalter simuliert werden. (Nur für EVSE die diese Funktion unterstützen) Anzeige der Phasenspannungen über LEDs Prüfen von E-Ladestationen auch bei fest angeschlossenem Ladekabel Zur Fahrzeugsimulation (CP): Gemäß IEC 61851 können die Zustände A, B, C, D und E simuliert werden. Die verschiedenen Fahrzeugzustände werden über den Drehschalter eingestellt. Zustand A: kein Fahrzeug angeschlossen Zustand B: Fahrzeug angeschlossen, aber nicht bereit zum Laden Zustand C: Fahrzeug angeschlossen und bereit zum Laden, Belüftung des Ladebereichs nicht gefordert Zustand D: Fahrzeug angeschlossen und bereit zum Laden, Belüftung des Ladebereichs gefordert Zustand E: Fehler: Kurzschluss CP-PE über interne Diode Zur Kabelsimulation (PP): Es können die verschiedenen Codierungen für Ladekabel mit 13, 20, 32 und 63 A simuliert werden. Außerdem ist es möglich, den Zustand -kein Kabel- zu simulieren. Die Simulation der verschiedenen Ladekabel erfolgt durch Schalten verschiedener Widerstande zwischen PP und PE mithilfe des Drehschalters. Gemäss IEC 61851 sind folgende Werte möglich: Kein Kabel: ∞ Ohm 13 A Kabel: 1,5 k Ohm 20 A Kabel: 680 Ohm 32 A Kabel: 220 Ohm 63 A Kabel. 100 Ohm
CS-4001PM/127 – Mobile Prüfeinrichtungen

CS-4001PM/127 – Mobile Prüfeinrichtungen

Messpunkte Blockspannungen 127 Batteriespannung 2 Messsystem 2 Strom 2 Temperatur 2 DC Eingangsbereich Blockspannung 15 V Maximale Potentialdifferenz an einem Stecker (C1-C8) 250 V / Stecker (600 V in total) Batteriespannung 600 V Strom (zwei Bereiche) 100mV / 1V Während eines Kapazitätstests können sich die Blockspannungen einer Batterie schnell verändern. Diese Veränderungen können am Anfang (der sog. Spannungssack) und am ende einer Entladung auftreten. Das CS-4001PM ist ein mehrkanaliges Prüfsystem, mit dem diese Spannungsveränderungen genau erfasst und aufgezeichnet werden. Neben der Blockspannungsmessung werden der Lade-/Entladestrom, die Batteriegesamtspannung und die Temperatur mit aufgezeichnet. Das Testsystem ermöglicht zusätzlich das Prüfen von zwei Batterieanlagen gleichzeitig. Alle Messpunkte werden in ca. 6 Sekunden erfasst und gespeichert. Das CS-4001PM ermöglicht proffessionelle Kapazitätstest einfach und sicher zu gestalten. Diese neue Generation von mobilen Bateriescannern löst das Vorgängermodell CS-4001 ab. Das CS-4001PM wurde vollständig neue entwickelt und beinhaltet keine mechanischen Kontakte (Relais) zur Selektion der verschiedenen Blockspannungen.